Ductile Iron Flange Type DN150 6′′ Preaction Alarm Valve Zsfy for Fire Protection

Product Details
Customization: Available
Sprinkler Installation: Ordinary
Sprinkler Head Type: Closed
Still deciding? Get samples of US$ 230/Piece
Request Sample
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
50000000 RMB
Plant Area
>2000 square meters
  • Ductile Iron Flange Type DN150 6′′ Preaction Alarm Valve Zsfy for Fire Protection
  • Ductile Iron Flange Type DN150 6′′ Preaction Alarm Valve Zsfy for Fire Protection
  • Ductile Iron Flange Type DN150 6′′ Preaction Alarm Valve Zsfy for Fire Protection
  • Ductile Iron Flange Type DN150 6′′ Preaction Alarm Valve Zsfy for Fire Protection
  • Ductile Iron Flange Type DN150 6′′ Preaction Alarm Valve Zsfy for Fire Protection
Find Similar Products

Basic Info.

Model NO.
ZSFY150
Automatically Opened and Closed Repeatedly
Can Automatically Opened and Closed
Open Fire Sprinkler System Type
Water Spray System
Closed Fire Sprinkler System
Preaction Fire Sprinkler System
Alarm Valve Diameter
150mm
Deluge Valve Type
Diaphragm Type
Certificate
CCC
Transport Package
Wooden Case
Specification
DN150 6′′
Trademark
Longdu/OEM
Origin
Cn
HS Code
8481804090
Production Capacity
500000PCS/Year

Product Description

Introduction of Pre-action Alarm Valve

 

Pre-action fire sprinkler systems are filled with air and water is only allowed to pass through when the smoke alarm or detector goes off. This type of system requires two triggers to start water flow. It helps greatly that the pre-action fire sprinkler can be set to prevent water from spouting in case of a false alarm or a mechanical failure.

The pre-action system is good for use in places where the sprinklers are only necessary when there is an actual fire so other items in the building do not get water damage from an accidental sprinkling. They are usually employed in freezing cold areas and areas with valuable items that are in need of avoiding water damage due to damaged sprinklers and/or piping, such as computer lab, generator room, reference room, document room and warehouse etc. Mistaken extinguishing is not allowed in such important places.

 

How does it work?

The pre-action system is a fire extinguishing system with the nozzles normally closed, the pipe network is usually not filled with water. When a fire occurs, after the fire detector alarms, the automatic control system controls the valve exhaust and water filling, and changes from a dry type to a wet type system. Water spraying only starts when the ignition point temperature reaches the point where the sprinklers are actuated.

The pre-action system has the characteristics of both a dry sprinkler system and a wet sprinkler system,and also overcomes the shortcomings of the dry sprinkler system's low fire control rate and the wet system's prone to water stains. But it requires higher for cost and maintenance. 


Technical Parameters
Ductile Iron Flange Type DN150 6′′ Preaction Alarm Valve Zsfy for Fire Protection

Flange Type&Specs.
D=flange outer diameter; K=bolt hole diameter; L=bolt diameter; n=bolt hole number; C=flange thickness
Ductile Iron Flange Type DN150 6′′ Preaction Alarm Valve Zsfy for Fire Protection

Our Advantages

1. Manufacturer direct supply with reasonable price.

2. Fully assembled in factory and convenient for customers to install.

3. Strict quality check before export.

4. Customized OEM order is accepted.

5. Technical support available.
6. Wide product range of foam system and water sprinkler system.
Ductile Iron Flange Type DN150 6′′ Preaction Alarm Valve Zsfy for Fire ProtectionDuctile Iron Flange Type DN150 6′′ Preaction Alarm Valve Zsfy for Fire ProtectionDuctile Iron Flange Type DN150 6′′ Preaction Alarm Valve Zsfy for Fire Protection

Ductile Iron Flange Type DN150 6′′ Preaction Alarm Valve Zsfy for Fire ProtectionDuctile Iron Flange Type DN150 6′′ Preaction Alarm Valve Zsfy for Fire Protection
Ductile Iron Flange Type DN150 6′′ Preaction Alarm Valve Zsfy for Fire Protection

Ductile Iron Flange Type DN150 6′′ Preaction Alarm Valve Zsfy for Fire ProtectionDuctile Iron Flange Type DN150 6′′ Preaction Alarm Valve Zsfy for Fire ProtectionFAQ

1. Are you a manufacturer or a trading company?
- Manufacturer, 100%, located in Nan'an City, Quanzhou, Fujian Province, China.

2. Can we pay a visit to your factory?
- Sure, we warmly welcome all customers to inspect our factory.

3. What products do you manufacture?
- Wide product range of fire fighting foam system and fire sprinkler system, such as foam bladder tanks,  foam concentrates, fire hoses, sprinkler heads, hydrants, gate valves, alarm valves and so on. 

4. What is your sample policy?
- For small items, we offer FREE SAMPLES for sample evaluation purpose, but customers need to pay for the shipping; For large and heavy items, we charge for the samples, but the charge will be refunded to customer when the order quantity reaches certain amount. 

5. What is your payment method?
- T/T, L/C, Paypal, Western Union etc. 

6. What is your delivery time?
- We have READY STOCK of some products(such as sprinkler heads, hoses, hydrants etc.), which allows for quick delivery within a week,  for other items or OEM orders, the delivery time is normally within one month. The quicker the payment from you, the sooner the delivery time will be:)

7. Which is your loading port from China?
- Xiamen port by sea or by air, and this year we are going to launch a NEW PLANT in Shandong province, so some products may ship from Rizhao or Qingdao port. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier